| Peer-Reviewed

Bacteriological Assessment of Stethoscope Used by Health Care Personnel in Attat Hospital, Snnp, Gurage Zone, Ethiopia

Received: 26 November 2021     Accepted: 21 December 2021     Published: 5 February 2022
Views:       Downloads:
Abstract

The stethoscope has always been an important element of a physician's toolkit when it comes to examining patients. The widespread use of stethoscopes by health-care workers for patient examinations makes them a potential source of nosocomial infection transmission. The goal of this study was to see if stethoscopes used by different health-care professionals in Attat Hospital may transmit bacteria. From April to June 2018, a cross-sectional study was done in the molecular laboratory of Wolkite University's department of biotechnology and biology. A total of 26 stethoscopes from health workers who had direct contact with patients were gathered during the study period. The sample was obtained using a sterile cotton-tipped applicator saturated in a sterile solution of physiologic saline (0.85% sodium chloride) to swab the whole surface of the stethoscope's diaphragm and then inoculated into macconkey agar, tryptone soya agar, and blood agar medium. 18 (69.2%) stethoscopes out of total collected stethoscopes had bacterial growth, and 12 bacterial isolates were selected and characterized to genus level. Isolates include staphylococcus aureus (37.5%), coagulase negative staphylococci (28.12%), Streptococcus sp. (21.88%), and Bacillus sp. (12.5%). All isolates were susceptible to the co-trimoxazole and ciprofloxacine, while resistant to cifoxitine. They showed intermediate growth against vancomycine. All except streptococcus were found resistant against penicillin. Both S. aureus and CoNS were sensitive to the chloramphenicol; Streptococcus was intermediate while bacillus was resistant to the chloramphenicol. All stethoscopes (42.2%) that had never been cleaned and were last cleaned a week ago were severely contaminated, while those washed multiple times a day and cleansed between each patient before the examination of the patient had lower levels of contamination (27%).

Published in International Journal of Microbiology and Biotechnology (Volume 7, Issue 1)
DOI 10.11648/j.ijmb.20220701.11
Page(s) 1-10
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2022. Published by Science Publishing Group

Keywords

Isolates, Nosocomial Infection, Stethoscope

References
[1] Adetunji, C., Makanjuola, O., Lateef, A., Oloke, J., Arowora, K., Adetunji, J., Ajani, A., Africa-Purino, F., Dy, E. and Coronel, R. (2001). Stethoscopes: a potential source of nosocomial infections. Phil. J. Microbiol. Infect. Dis. 29: 9-13.
[2] Al-hamad A, Maxwell S. 2010 How clean is clean? Proposed methods for hospital cleaning assessment. J Hosp Infect; 70: 328-33.
[3] Alothman A, Bukhari A, Aljohani S, Muhanaa A. 2009 Should we recommend stethoscope disinfection before daily usage as an infection control rule? The Open Infectious Diseases Journal; 3: 80-2.
[4] Aneja, K. (2003). Experiments in Microbiology, Plant Physiology and Biotechnology, 4th edn. New Age International, New Delhi.
[5] Aslanzadeh, J. (2006). Biochemical profile-based microbial identification systems. In: Advanced Techniques in Diagnostic Microbiology, pp. 84-116, (Tang, Y. and Stratton, C., eds). Springer Science+Business Media, New York.
[6] Atlas, R. (2010). Handbook of Microbiological Media, 4th edn. CRC Press Taylor & Francis Group, Boca Raton.
[7] Chigozie, J., Annayo, O., Patrick, G. and Christian, M. (2010). Bacteria contamination of stethoscopes used by health workers: public health implications. J. Infect. Dev. Ctries.; 4: 436-41.
[8] Cheesbrough M. (2006). District Laboratory Practice in Tropical Countries, Part 2, Cambridge University Press, United Kingdom, PP 60-64.
[9] Fenelon, L., Holcroft, L. and Waters, N. (2009). Contamination of stethoscopes with MRSA and current disinfection practices. J. Hosp. Infect. 71: 376-378.
[10] Gastmeier, P., Groneberg, K., Weist, K. andRüden, H. (2003). A cluster of nosocomial Klebsiella pneumonia bloodstream infections in a neonatal intensive care department: Identification of transmission and intervention. Am. J. Infect. Contr. 3: 424-430.
[11] Gregorson, G. (1978). Rapid method for distinction of gram negative from gram positive bacteria. European J. Appl. Microbiol. 5: 123-127.
[12] Gupta, A., Della-Latta, P., Todd, B., San Gabriel, P., Haas, J., Wu, F., Rubenstein, D. andSaiman, L. (2004). Outbreak ofextendedspectrum beta-lactamase-producing Klebsiella pneumonia in a neonatal intensive care unit linked to artificial nails. Infect. Contr. Hosp. Epidemiol. 25: 210-215.
[13] Harisha, S. (2007). Biotechnology Procedures and Experiments Handbook. Infinity Science Press, Hingham.
[14] Harley, J. and Prescott, L. (2002). Laboratory Exercise in Microbiology, 5th edn. The McGraw−Hill Companies, 466p.
[15] Holt, J. G., Krieg, N. R., Sneath, P. H. A. and Staley, J. T. (1994). Bergey’s Manual of Determinative Bacteriology, 9th edn. Williams and Wilkins company, Baltimore, MD, USA, pp: 255-273.
[16] Kerr, J. R., Martin, H., Chadwick, M. V., Edwards, A., Hodson, M. E. and Geddes, D. M. (2002). Evidence against transmission of Pseudomonas aeruginosaby hands and stethoscopes in a cystic fibrosis unit. J. Hosp. Infect. 50: 324-326.
[17] Lahsaeizadeh S, Jafari H, Askarian M. Health care associated infection in Shiraz, Iran 2004-2005. J Hosp Infect. 2009; 69: 283-7.
[18] Madar, R., Novakova, E. and Baska, T. (2005). The role of noncritical health-care tools in the transmission of nosocomial infections. Bratisl. Lek. Listy. 106: 348-350.
[19] Marinella MA, Pierson C, Chenoweth C 1997. The Stethoscope- a potential source of nosocomial infection? Arch Intern Med; 157: 786-70.
[20] Merlin, M. A., Wong, M. L., Pryor, P. W., Rynn, K., MarquesBaptista, A., Perritt, R., Stanescu, C. G. and Fallon, T. (2009). Prevalence of methicillin-resistant Staphylococcus aureus on the stethoscopes of emergency medical services providers. Prehosp. Emerg. Care. 13: 71-74.
[21] Orrett, F. A., Brooks, P. J. and Richardson, E. G. (1998). Nosocomial infections in a rural regional hospital in a developing country: infection rates by site, service, cost, and infection control practices. Infect. Contr. Hosp. Epidemiol. 19: 136-140.
[22] Parmar, R. C., Valvi, C. C., Sira, P. andKamat, J. R. (2004). A prospective, randomised, double-blind study of comparative efficacy of immediate versus daily cleaning of stethoscope using 66% ethyl alcohol. Indian J. Med. Sci. 58: 423-430.
[23] PatentStorm (2004) Disposable cover for stethoscope head. Available: http://www.freepatentsonline.com/5747751.html. Accessed 15 October 2009.
[24] Rahman L, and Anson KR. (2004). Bacterial contamination of hospital physicians’ stethoscopes. Infect. Control Hospital Epidemiol. 20 (9): 626-628.
[25] Raka L, Zoutman D, Mulliqi G, Krasniqi S, Dedushaj I, Raka N, Ahmeti S, Shala M, Vishaj A, Elezi Y. Prevalence of nosocomial infections in high-risk units in the University Clinical Center of Kosovo. Infect ContrHospEpidemiol 2006; 27: 421-423.
[26] Saloojee, H. and Steenhoff, A. (2001). The health professional's role in preventing nosocomial infections. Postgrad. Med. J. 77: 16-19.
[27] Schroeder, A., Schroeder, M. A. and D'Amico, F. (2009). What’s growing on your stethoscope? (and what you can do about it). J. Fam. Pract. 58: 404-409.
[28] Sengupta S, Sirkar A, Shivananda PG (2000) Stethoscopes and nosocomial infection. Indian J Pediatr 67: 197-199.
[29] Shiferaw, T., Beyene, G., Kassa, T. and Sewunet, T. (2013). Bacterial contamination, bacterial profile and antimicrobial susceptibility pattern of isolates from stethoscopes at Jimma University Specialized Hospital. Annals of Clinical Microbiology and Antimicrobials 12: 39.
[30] Singh G,. Urhekar A. D, Hodiwala A. V, Singh N, Das B. 2013 Bacterial contamination of stethoscopes used by health care workers in a tertiary care hospital in Navi Mumbai. IJPBS; 3 (1) 186-193.
[31] Uneke, C. J., Ogbonna, A., Oyibo, P. G. and Ekuma, U. (2008). Bacteriological assessment of stethoscopes used by medical students in Nigeria: Implications for nosocomial infection control. World Health Popul. 10: 53-61.
[32] Vincent, J. L. (2003). Nosocomial infections in adult intensive care units. Lancet 361: 2068-2077.
[33] Weinstein RL, Restrepo RD, Bourne KC, Daher N. 2005. Contamination level of stethoscopes used by physicians and physicians Assistants. The J of Physician Assistant Edu. 18: 41-3.
[34] WHO (2002). Prevention of Hospital-Acquired Infections: A Practical Guide. Malta: Department of Communicable Disease, Surveillance and Response.
[35] World Health Organization (2009) WHO Guidelines for Hand Hygiene in Health Care. First Global Patient Safety Challenge Clean Care is Safer Care. Geneva: WHO, 270p.
[36] WHO (2009). Save Lives Clean Your Hands-Guide to Implementation. A Guide to the Implementation of the WHO Multimodal Hand Hygiene Improvement Strategy WHO/IER/PSP/2009.02. Geneva: WHO 48p.
[37] Yemane, T. (1967). Statstics: An Introductory Analysis, 2nd edn. New York: Harper and Row, S. A. (2002). Stethoscope: a friend or an enemy? Sao Paulo Med. J. 120: 13 15.
Cite This Article
  • APA Style

    Tamirat Salile Sada. (2022). Bacteriological Assessment of Stethoscope Used by Health Care Personnel in Attat Hospital, Snnp, Gurage Zone, Ethiopia. International Journal of Microbiology and Biotechnology, 7(1), 1-10. https://doi.org/10.11648/j.ijmb.20220701.11

    Copy | Download

    ACS Style

    Tamirat Salile Sada. Bacteriological Assessment of Stethoscope Used by Health Care Personnel in Attat Hospital, Snnp, Gurage Zone, Ethiopia. Int. J. Microbiol. Biotechnol. 2022, 7(1), 1-10. doi: 10.11648/j.ijmb.20220701.11

    Copy | Download

    AMA Style

    Tamirat Salile Sada. Bacteriological Assessment of Stethoscope Used by Health Care Personnel in Attat Hospital, Snnp, Gurage Zone, Ethiopia. Int J Microbiol Biotechnol. 2022;7(1):1-10. doi: 10.11648/j.ijmb.20220701.11

    Copy | Download

  • @article{10.11648/j.ijmb.20220701.11,
      author = {Tamirat Salile Sada},
      title = {Bacteriological Assessment of Stethoscope Used by Health Care Personnel in Attat Hospital, Snnp, Gurage Zone, Ethiopia},
      journal = {International Journal of Microbiology and Biotechnology},
      volume = {7},
      number = {1},
      pages = {1-10},
      doi = {10.11648/j.ijmb.20220701.11},
      url = {https://doi.org/10.11648/j.ijmb.20220701.11},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ijmb.20220701.11},
      abstract = {The stethoscope has always been an important element of a physician's toolkit when it comes to examining patients. The widespread use of stethoscopes by health-care workers for patient examinations makes them a potential source of nosocomial infection transmission. The goal of this study was to see if stethoscopes used by different health-care professionals in Attat Hospital may transmit bacteria. From April to June 2018, a cross-sectional study was done in the molecular laboratory of Wolkite University's department of biotechnology and biology. A total of 26 stethoscopes from health workers who had direct contact with patients were gathered during the study period. The sample was obtained using a sterile cotton-tipped applicator saturated in a sterile solution of physiologic saline (0.85% sodium chloride) to swab the whole surface of the stethoscope's diaphragm and then inoculated into macconkey agar, tryptone soya agar, and blood agar medium. 18 (69.2%) stethoscopes out of total collected stethoscopes had bacterial growth, and 12 bacterial isolates were selected and characterized to genus level. Isolates include staphylococcus aureus (37.5%), coagulase negative staphylococci (28.12%), Streptococcus sp. (21.88%), and Bacillus sp. (12.5%). All isolates were susceptible to the co-trimoxazole and ciprofloxacine, while resistant to cifoxitine. They showed intermediate growth against vancomycine. All except streptococcus were found resistant against penicillin. Both S. aureus and CoNS were sensitive to the chloramphenicol; Streptococcus was intermediate while bacillus was resistant to the chloramphenicol. All stethoscopes (42.2%) that had never been cleaned and were last cleaned a week ago were severely contaminated, while those washed multiple times a day and cleansed between each patient before the examination of the patient had lower levels of contamination (27%).},
     year = {2022}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Bacteriological Assessment of Stethoscope Used by Health Care Personnel in Attat Hospital, Snnp, Gurage Zone, Ethiopia
    AU  - Tamirat Salile Sada
    Y1  - 2022/02/05
    PY  - 2022
    N1  - https://doi.org/10.11648/j.ijmb.20220701.11
    DO  - 10.11648/j.ijmb.20220701.11
    T2  - International Journal of Microbiology and Biotechnology
    JF  - International Journal of Microbiology and Biotechnology
    JO  - International Journal of Microbiology and Biotechnology
    SP  - 1
    EP  - 10
    PB  - Science Publishing Group
    SN  - 2578-9686
    UR  - https://doi.org/10.11648/j.ijmb.20220701.11
    AB  - The stethoscope has always been an important element of a physician's toolkit when it comes to examining patients. The widespread use of stethoscopes by health-care workers for patient examinations makes them a potential source of nosocomial infection transmission. The goal of this study was to see if stethoscopes used by different health-care professionals in Attat Hospital may transmit bacteria. From April to June 2018, a cross-sectional study was done in the molecular laboratory of Wolkite University's department of biotechnology and biology. A total of 26 stethoscopes from health workers who had direct contact with patients were gathered during the study period. The sample was obtained using a sterile cotton-tipped applicator saturated in a sterile solution of physiologic saline (0.85% sodium chloride) to swab the whole surface of the stethoscope's diaphragm and then inoculated into macconkey agar, tryptone soya agar, and blood agar medium. 18 (69.2%) stethoscopes out of total collected stethoscopes had bacterial growth, and 12 bacterial isolates were selected and characterized to genus level. Isolates include staphylococcus aureus (37.5%), coagulase negative staphylococci (28.12%), Streptococcus sp. (21.88%), and Bacillus sp. (12.5%). All isolates were susceptible to the co-trimoxazole and ciprofloxacine, while resistant to cifoxitine. They showed intermediate growth against vancomycine. All except streptococcus were found resistant against penicillin. Both S. aureus and CoNS were sensitive to the chloramphenicol; Streptococcus was intermediate while bacillus was resistant to the chloramphenicol. All stethoscopes (42.2%) that had never been cleaned and were last cleaned a week ago were severely contaminated, while those washed multiple times a day and cleansed between each patient before the examination of the patient had lower levels of contamination (27%).
    VL  - 7
    IS  - 1
    ER  - 

    Copy | Download

Author Information
  • Department of Biotechnology, Wolkite University, Wolkite Shewa, Ethiopia

  • Sections